APPENDIX F – SIDECHAIN / LOOPTHROUGH CONNECTION MODES
ENG
Axel Technology srl
www.axeltechnology.com
External Synch MUST be enabled from the control panel menu or from the Pc control software
MPX pilot suitable level: minimum 100 mVpp, max 1,9 Vpp
19 kHz Sync tolerance : +/- 5Hz to lock; +/- 15 Hz to unlock
An automatic switchover to internal oscillator in case of absence or low quality of external reference
signal is performed.
The level of the injected signal may be adjusted by means of the trimmer next to the corresponding
BNC connector (no software control is provided for this purpose). This trimmer is factory preset for a
gain of 0 dB.
MPX + RDS (TX In)
MPX+RDS Out
AUX1-MPX
MPX Out
BARRACUDA
Only as RDS Coder
MPX Encoder
(ie TigerShark-R,
Shark,Falcon Five)
Transmitter
Analogic INPUT
coming from
MAIN OUT